G6K(U)-2F(P)-RF(-S, -T) Surface-mounting High-frequency Relay
Surface-mounting, 1-GHz-Band/3-GHz-Band, Miniature, DPDT, High-frequency Relay
- Superior high-frequency characteristics (at 1 GHz), such as an isolation of 20 dB min. between contacts of the same polarity of 30 dB min. between contacts of different polarity with an insertion loss of 0.2 dB max.
- Miniaturized to 10.3 × 6.9 × 5.4 mm (L × W × H).
- Rated power consumption of 100 mW with high sensitivity
- Single-side stable and single-winding latching models are available.
- Models with a smaller footprint (G6K(U)-2F-RF-S) are available to help save space.
- G6K(U)-2F-RF-T models for 3-GHz band join the lineup with a downsized footprint.
- New PCB terminals models are available.
Standard Specifications
Relay Function | Enclosure rating | Contact form | Rated coil voltage | Model | Minimum packing unit |
---|---|---|---|---|---|
Single-side stable | Fully sealed | DPDT(2c) | 3, 4.5, 5, 12, 24 VDC | G6K-2F-RF | 300 pcs/tray 300 pcs/reel |
Single-winding latching | 3, 4.5, 5, 12, 24 VDC | G6KU-2F-RF |
Board space-saving model
Relay Function | Enclosure rating | Contact form | Rated coil voltage | Model | Minimum packing unit |
---|---|---|---|---|---|
Single-side stable | Fully sealed | DPDT(2c) | 3, 4.5, 5, 12, 24 VDC | G6K-2F-RF-S | 300 pcs/tray 300 pcs/reel |
Single-winding latching | 3, 4.5, 5, 12, 24 VDC | G6KU-2F-RF-S |
Compatible with 3 GHz
Relay Function | Enclosure rating | Contact form | Rated coil voltage | Model | Minimum quantity packaged |
---|---|---|---|---|---|
Single-side stable | Fully sealed | DPDT(2c) | 3, 4.5, 5, 12, 24 VDC | G6K-2F-RF-T | 300 pcs/tray 300 pcs/reel |
Single-winding latching | 3, 4.5, 5, 12, 24 VDC | G6KU-2F-RF-T |
PCB terminals
Relay Function | Enclosure rating | Contact form | Rated coil voltage | Model | Minimum packing unit |
---|---|---|---|---|---|
Single-side stable | Fully sealed | DPDT(2c) | 3, 4.5, 5, 12, 24 VDC | G6K-2P-RF | 30 pcs/tube |
Note 1. | When ordering, add the rated coil voltage to the model number. | ||
Example: G6K-2F-RF | |||
However, the notation of the coil voltage on the product case as well as on the packing will be marked as □□ VDC. | |||
Note 2. | When ordering Relays in tape packing, add "-TR03" to the end of the model number. Example: G6K-2F-RF-TR03 DC3 |
||
|
|||
Be sure since "-TR" is not part of the relay model number, it is not marked on the relay case. When ordering tape packing, minimum order unit is 1 reel (300 pcs ✕ 1 = 300 pcs). |
Single-side Stable
(G6K-2F(P)-RF(-S, -T))
Rated voltage (VDC) | 3 | 4.5 | 5 | 12 | 24 | |
---|---|---|---|---|---|---|
Rated current (mA) | 33.0 | 23.2 | 21.1 | 9.1 | 4.6 | |
Coil resistance (Ω) | 91 | 194 | 237 | 1,315 | 5,220 | |
Must operate voltage (V) | % of rated voltage | 80% max. of rated voltage | ||||
Must release voltage (V) | 10% min. of rated voltage | |||||
Maximum voltage (V) | 150% of rated voltage | |||||
Power consumption (mW) | Approx. 100 |
Single-winding Latching Models
(G6KU-2F-RF(-S, -T))
Rated voltage (VDC) | 3 | 4.5 | 5 | 12 | 24 | |
---|---|---|---|---|---|---|
Rated current (mA) | 33.0 | 23.2 | 21.1 | 9.1 | 4.6 | |
Coil resistance (Ω) | 91 | 194 | 237 | 1,315 | 5,220 | |
Must set voltage (V) | % of rated voltage | 75% max. of rated voltage | ||||
Must reset voltage (V) | 75% max. of rated voltage | |||||
Maximum voltage (V) | 150% of rated voltage | |||||
Power consumption (mW) | Approx. 100 |
Note: | 1. | The rated current and coil resistance are measured at a coil temperature of 23ºC with a tolerance of ±10%. |
2. | The Operating characteristics are measured at a coil temperature of 23ºC. | |
3. | The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously. |
Contact Ratings
Load | Resistive load |
---|---|
Rated load | 125 VAC, 0.3 A 30 VDC, 1 A 1 GHz, 1W * |
Rated carry current | 1A |
Max. switching voltage | 125 VAC or 60 VDC |
Max. switching current | 1A |
High-frequency Characteristics *1
|
G6K(U)-2F(P)-RF(-S) | G6K(U)-2F-RF-T | ||||||
---|---|---|---|---|---|---|---|---|
1 GHz | 1 GHz | 3 GHz | ||||||
Isolation | Between contacts of the same polarity | 20 dB min. | 20 dB min. | 18 dB min. | ||||
Between contacts of the different polarity | 30 dB min. | 25 dB min. | 25 dB min. | |||||
Insertion loss | 0.2 dB max. | 0.2 dB max. | 0.6 dB max. | |||||
V.SWR | 1.2 max. | 1.2 max. | 1.4 max. | |||||
Maximum carry power | 3 W *1 | |||||||
Maximum switching power | 1 W *2 |
Note: | 1. | The impedance of the measurement system is 50 Ω. |
2. | The above values are initial values. | |
*1 | Contact your OMRON representative if the Relay will be used in an application that requires high repeatability in high-frequency characteristics for the microload region. (Such applications include testing and measurement equipment and ATE applications.) | |
*2 | These values are for a V.SWR of 1.2 max. at the load. |
Characteristics
|
Single-side stable models | Single-winding latching models | |||||||
---|---|---|---|---|---|---|---|---|---|
G6K-2F(P)-RF(-S, -T) | G6KU-2F-RF(-S,T) | ||||||||
Contact resistance *1 | 100 mΩ max. | ||||||||
Operating (set) time *2 | 3 ms max. (approx. 1.4 ms) | 3 ms max. (approx. 1.2 ms) | |||||||
Release (reset) time *2 | 3 ms max. (approx. 1.3 ms) | 3 ms max. (approx. 1.2 ms) | |||||||
Minimum set/reset pulse time | --- | 10 ms | |||||||
Insulation resistance *3 | 1,000 M Ω min. (at 500 VDC) | ||||||||
Dielectric strength | Between coil and contacts | 750 VAC, 50/60 Hz for 1 min | |||||||
Between contacts of different polarity | 750 VAC, 50/60 Hz for 1 min | ||||||||
Between contacts of the same polarity | 750 VAC, 50/60 Hz for 1 min | ||||||||
Between ground and coil/contacts | 500 VAC, 50/60 Hz for 1 min | ||||||||
Vibration resistance | Destruction | 10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude) and 55 to 500 Hz, 300 m/s2 | |||||||
Malfunction | 10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) and 55 to 500 Hz, 200 m/s2 | ||||||||
Shock resistance |
Destruction | 1,000 m/s2 | |||||||
Malfunction | 750 m/s2 | ||||||||
Durability | Mechanical | 50,000,000 operations min. (at a switching frequency of 36,000 operations/hour) | |||||||
Electrical | 100,000 operations min. (at a switching frequency of 1,800 operations/hour) | ||||||||
Ambient operating temperature | -40ºC to 70ºC (with no icing or condensation) | ||||||||
Ambient operating humidity | 5% to 85% | ||||||||
Weight | Approx. 0.95 g |
Note: | The above values are initial values. | |
1. | The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method. | |
2. | Values in parentheses are actual values. | |
3. | The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength. |
Standard Specifications G6K-2F-RF G6KU-2F-RF |
||||||||||
Mounting Dimensions (Top View) Tolerance:±0.1mm |
Terminal Arrangement/ Internal Connections (Top View) Note:Check carefully the coil polarity of the Relay. |
|||||||||
|
||||||||||
Board space-saving model G6K-2F-RF-S G6KU-2F-RF-S |
||||||||||
Mounting Dimensions (Top View) Tolerance:±0.1mm |
Terminal Arrangement/ Internal Connections (Top View) Note:Check carefully the coil polarity of the Relay. |
|||||||||
|
||||||||||
Compatible with 3 GHz G6K-2F-RF-T, G6KU-2F-RF-T |
||||||||||
Mounting Dimensions (Top View) Tolerance:±0.1mm PCB information Layer Structure: 2L Finished Thickness: 0.6 mm Copper Thickness: 18 μm |
Terminal Arrangement/ Internal Connections (Top View) Note:Check carefully the coil polarity of the Relay. |
|||||||||
|
||||||||||
PCB terminals G6K-2P-RF |
||||||||||
Mounting Dimensions (BOTTOM VIEW) Tolerance:±0.1mm PCB information Layer Structure: 2L Finished Thickness: 0.6 mm Copper Thickness: 18 μm |
Terminal Arrangement/ Internal Connections (BOTTOM VIEW) Note:Check carefully the coil polarity of the Relay. |
|||||||||
|
Correct Use
●Relay Handling
Use the Relay as soon as possible after opening the moisture- proof package. If the Relay is left for a long time after opening the moisture-proof package, the appearance may suffer and seal fail- ure may occur after the solder mounting process. To store the Relay after opening the moisture-proof package, place it into the original package and seal the package with adhesive tape.
When washing the product after soldering the Relay to a PCB, use a water-based solvent or alcohol-based solvent and keep the solvent temperature to less than 40℃. Do not put the Relay in a cold cleaning bath immediately after soldering.
●Environmental Conditions for Usage, Storage,and Transport
Avoid direct sunlight when using, storing, or transporting the Relay and maintain normal temperature, humidity, and pressure conditions.
●Long-term, Continuous ON Contacts
Using the Relay in a circuit where the Relay will be ON continu- ously for long periods (rather than switching) can lead to unstable contacts because the heat generated by the coil itself will affect the insulation and can cause a film to develop on the contact sur- faces. We recommend using a latching relay (magnetic-holding relay) in this kind of circuit. If a single-side stable model must be used in this kind of circuit, we recommend adding fail-safe circuits in case the contact fails or the coil burns out.
●Claw Securing Force During Automatic Mounting
During automatic insertion of Relays, be sure to set the securing force of each claw to the following so that the Relay's characteris- tics will be maintained.
●Coating
Do not use silicone coating to coat the Relay when it is mounted to the PCB. Do not wash the PCB after the Relay is mounted using detergent containing silicone. Otherwise, the detergent may remain on the surface of the Relay.
●Repeatability
Contact your OMRON representative if the Relay will be used in an application that requires high repeatability in high-frequency characteristics for the microload region. (Such applications include testing and measurement equipment and ATE applications.)
●About use of an IC socket.
For: G6K-2P-RF
When using IC sockets, select IC sockets by confirming that the sockets Rated/Spec./Characteristics are within the range of using condition.
Also, confirm whether there is any problem of electric capability or plug insertion or not with actual using condition.
●Others
For: G6K-2P-RF
The dotted line below on the surface of relay is connected with a metal case (ground).
So confirm the actual influence of insulation and signal characteristics when designing.